I'm getting some silly readings from the O/2 sensor,the log looks more like a seismograph.I have the sensor about 8 inches from the header pipe merge in the bend inward toward the "X" .
Monte said it's most likely in a turbulent location.The sensor is at the 9 o'clock position.

SO where IS the sweet spot to install the sensor??? runaway

Last edited by hemi-itis; 03/01/16 01:57 PM.

HEMI-ITIS has no cure.
My condition is fully BLOWN!!
Re: O/2 sensor location,where is the sweet spot??????? [Re: hemi-itis] #2022560
03/01/16 01:38 PM
03/01/16 01:38 PM
Joined: Jun 2003
Posts: 52,972
Romeo MI
MR_P_BODY Offline
Master
MR_P_BODY  Offline
Master

Joined: Jun 2003
Posts: 52,972
Romeo MI
I put them in a straight run area.. about 6"
after the end of the primaries.. if yu were
running open headers I want 8"-10" before the
end of the collector.. that way it wont back
flow and pick up out side air which could give
you bogus readings on shut down or a steady rpm..
make sure the sensor is pointed a little downward
(on the inside) the drop off moisture when its
cooling... try not to put it near the X.. being that
just pulses back and forth
wave

Re: O/2 sensor location,where is the sweet spot??????? [Re: hemi-itis] #2022570
03/01/16 01:53 PM
03/01/16 01:53 PM
Joined: Feb 2008
Posts: 715
Central TEXAS!!!!
sr4440 Offline
super stock
sr4440  Offline
super stock

Joined: Feb 2008
Posts: 715
Central TEXAS!!!!
I have put sensors all over primary pipe, collector, before the merge, after and 8 inches down stream. I have never had a problem with reading jumping around. With that being said if there is high pressure hitting the O2 sensor the reading will change. On the dyno, when we do a turbo engine, I have a pressure sensor in the exhaust manifold that allows for a correction factor to be used.

this is from the Daytona sensor site, they have a chart that show the pressure relationship

Quote:
The Bosch LSU 4 wide-band sensor is affected by exhaust pressure as shown on the graph below. The error (%) applies to the oxygen pump cell current. Note that 1 bar corresponds to normal sea level atmospheric pressure. For most performance applications, excessive exhaust back pressure is not a concern and the resulting small error can be disregarded. At high elevations, the error is also relatively small. At 10,000 feet elevation (about .68 bar), AFR values near 13.0 will be shifted up approximately +0.15 AFR.


http://www.daytona-sensors.com/tech_wego.html

hope this helps


joe


Without Data, you’re just another guy with an opinion.
Re: O/2 sensor location,where is the sweet spot??????? [Re: hemi-itis] #2022582
03/01/16 02:17 PM
03/01/16 02:17 PM
Joined: Jan 2003
Posts: 8,028
Tulsa OK
Bad340fish Offline
master
Bad340fish  Offline
master

Joined: Jan 2003
Posts: 8,028
Tulsa OK
I would put your exhaust cutouts in before I moved the 02s, that back pressure could be causing the crazy readings.


68 Barracuda Formula S 340
Re: O/2 sensor location,where is the sweet spot??????? [Re: Bad340fish] #2022787
03/01/16 09:21 PM
03/01/16 09:21 PM
Joined: Jan 2007
Posts: 7,664
IN
A
ahy Offline
master
ahy  Offline
master
A

Joined: Jan 2007
Posts: 7,664
IN
Mine is mounted in the header collectors 2-3" upstream from the attachment flanges. This location has worked well for me... also what TTI recommended when they made the headers.

Re: O/2 sensor location,where is the sweet spot??????? [Re: hemi-itis] #2022840
03/01/16 10:41 PM
03/01/16 10:41 PM
Joined: Jan 2005
Posts: 2,540
Milwaukee WI
T
TRENDZ Offline
master
TRENDZ  Offline
master
T

Joined: Jan 2005
Posts: 2,540
Milwaukee WI
The sensor is junk. You could put it on the moon and it would still read lean.
Buy a new sensor, do a clean air calibration. Don't run the engine with ratios lower than 12.0:1.
Read the manufacturers mounting recommendation. Mount it in a position that is least likely to get any liquid on it.


"use it 'till it breaks, replace as needed"
Re: O/2 sensor location,where is the sweet spot??????? [Re: hemi-itis] #2022883
03/01/16 11:44 PM
03/01/16 11:44 PM
Joined: Aug 2011
Posts: 2,864
Pattison Texas
CSK Offline
master
CSK  Offline
master

Joined: Aug 2011
Posts: 2,864
Pattison Texas
has someone been using leaded fuel. & KILLED the o2 sensor ?


1968 Charger COLD A/C Hilborn EFI
512ci 9.7 compression, Stealth heads, 4.10 gear A518 ODtrans 4100lb,10.93 full street car trim
2020 T/A 392 Stock 11.79 @ 114.5

Re: O/2 sensor location,where is the sweet spot??????? [Re: CSK] #2022885
03/01/16 11:50 PM
03/01/16 11:50 PM
Joined: Dec 2007
Posts: 12,588
Great Neck,LI,new york
hemi-itis Offline OP
I Live Here
hemi-itis  Offline OP
I Live Here

Joined: Dec 2007
Posts: 12,588
Great Neck,LI,new york
Originally Posted By csk
has someone been using leaded fuel. & KILLED the o2 sensor ?


NO rant





That was the last set,,,,,,,,,,


HEMI-ITIS has no cure.
My condition is fully BLOWN!!
Re: O/2 sensor location,where is the sweet spot??????? [Re: TRENDZ] #2022893
03/02/16 12:04 AM
03/02/16 12:04 AM
Joined: Dec 2007
Posts: 12,588
Great Neck,LI,new york
hemi-itis Offline OP
I Live Here
hemi-itis  Offline OP
I Live Here

Joined: Dec 2007
Posts: 12,588
Great Neck,LI,new york
Originally Posted By TRENDZ
The sensor is junk. You could put it on the moon and it would still read lean.
Buy a new sensor, do a clean air calibration. Don't run the engine with ratios lower than 12.0:1.
Read the manufacturers mounting recommendation. Mount it in a position that is least likely to get any liquid on it.


Put a new set on before parking it for the winter.

Last edited by hemi-itis; 03/02/16 12:23 AM.

HEMI-ITIS has no cure.
My condition is fully BLOWN!!
Re: O/2 sensor location,where is the sweet spot??????? [Re: sr4440] #2022901
03/02/16 12:14 AM
03/02/16 12:14 AM
Joined: Dec 2007
Posts: 12,588
Great Neck,LI,new york
hemi-itis Offline OP
I Live Here
hemi-itis  Offline OP
I Live Here

Joined: Dec 2007
Posts: 12,588
Great Neck,LI,new york
Originally Posted By sr4440
I have put sensors all over primary pipe, collector, before the merge, after and 8 inches down stream. I have never had a problem with reading jumping around. With that being said if there is high pressure hitting the O2 sensor the reading will change. On the dyno, when we do a turbo engine, I have a pressure sensor in the exhaust manifold that allows for a correction factor to be used.

this is from the Daytona sensor site, they have a chart that show the pressure relationship

Quote:
The Bosch LSU 4 wide-band sensor is affected by exhaust pressure as shown on the graph below. The error (%) applies to the oxygen pump cell current. Note that 1 bar corresponds to normal sea level atmospheric pressure. For most performance applications, excessive exhaust back pressure is not a concern and the resulting small error can be disregarded. At high elevations, the error is also relatively small. At 10,000 feet elevation (about .68 bar), AFR values near 13.0 will be shifted up approximately +0.15 AFR.


http://www.daytona-sensors.com/tech_wego.html

hope this helps


joe




What's the difference between pressure & back pressure in the 4 inch pipe??

2.17.16 008.jpg

HEMI-ITIS has no cure.
My condition is fully BLOWN!!
Re: O/2 sensor location,where is the sweet spot??????? [Re: Bad340fish] #2022912
03/02/16 12:25 AM
03/02/16 12:25 AM
Joined: Dec 2007
Posts: 12,588
Great Neck,LI,new york
hemi-itis Offline OP
I Live Here
hemi-itis  Offline OP
I Live Here

Joined: Dec 2007
Posts: 12,588
Great Neck,LI,new york
Originally Posted By Bad340fish
I would put your exhaust cutouts in before I moved the 02s, that back pressure could be causing the crazy readings.


Shopping for pipe & v bands to fab cut outs up


HEMI-ITIS has no cure.
My condition is fully BLOWN!!
Re: O/2 sensor location,where is the sweet spot??????? [Re: hemi-itis] #2022921
03/02/16 12:31 AM
03/02/16 12:31 AM
Joined: Oct 2003
Posts: 7,506
Az
Crizila Offline
master
Crizila  Offline
master

Joined: Oct 2003
Posts: 7,506
Az
Could be a wiring problem - loose / bad ground can do that.


Fastest 300
Re: O/2 sensor location,where is the sweet spot??????? [Re: Crizila] #2022926
03/02/16 12:43 AM
03/02/16 12:43 AM
Joined: Dec 2007
Posts: 12,588
Great Neck,LI,new york
hemi-itis Offline OP
I Live Here
hemi-itis  Offline OP
I Live Here

Joined: Dec 2007
Posts: 12,588
Great Neck,LI,new york
Originally Posted By Crizila
Could be a wiring problem - loose / bad ground can do that.



work MMMMMMM


HEMI-ITIS has no cure.
My condition is fully BLOWN!!
Re: O/2 sensor location,where is the sweet spot??????? [Re: Crizila] #2023224
03/02/16 03:50 PM
03/02/16 03:50 PM
Joined: Feb 2008
Posts: 715
Central TEXAS!!!!
sr4440 Offline
super stock
sr4440  Offline
super stock

Joined: Feb 2008
Posts: 715
Central TEXAS!!!!
Originally Posted By Crizila
Could be a wiring problem - loose / bad ground can do that.


Bit confused by this, with no volts the O2 sensor (mine) will read 10.4 AFR and with full voltage (5 volts) it will read 19.5. So if it is a loose ground, I would expect a rich reading followed by a lean spike when it reconnected (maybe?). shruggy

Joe

Last edited by sr4440; 03/02/16 03:53 PM.

Without Data, you’re just another guy with an opinion.
Re: O/2 sensor location,where is the sweet spot??????? [Re: hemi-itis] #2023238
03/02/16 04:09 PM
03/02/16 04:09 PM
Joined: Jan 2005
Posts: 2,540
Milwaukee WI
T
TRENDZ Offline
master
TRENDZ  Offline
master
T

Joined: Jan 2005
Posts: 2,540
Milwaukee WI
Originally Posted By hemi-itis
Originally Posted By TRENDZ
The sensor is junk. You could put it on the moon and it would still read lean.
Buy a new sensor, do a clean air calibration. Don't run the engine with ratios lower than 12.0:1.
Read the manufacturers mounting recommendation. Mount it in a position that is least likely to get any liquid on it.


Put a new set on before parking it for the winter.

A new "set"?
Do you have 2 sensors?
Did you get the same results with the new sensor(s)?
I assume the wb control box has a +5v out. Are you also using a shared SIGNAL ground?


"use it 'till it breaks, replace as needed"
Re: O/2 sensor location,where is the sweet spot??????? [Re: TRENDZ] #2023379
03/02/16 07:45 PM
03/02/16 07:45 PM
Joined: Dec 2007
Posts: 12,588
Great Neck,LI,new york
hemi-itis Offline OP
I Live Here
hemi-itis  Offline OP
I Live Here

Joined: Dec 2007
Posts: 12,588
Great Neck,LI,new york
Originally Posted By TRENDZ
Originally Posted By hemi-itis
Originally Posted By TRENDZ
The sensor is junk. You could put it on the moon and it would still read lean.
Buy a new sensor, do a clean air calibration. Don't run the engine with ratios lower than 12.0:1.
Read the manufacturers mounting recommendation. Mount it in a position that is least likely to get any liquid on it.


Put a new set on before parking it for the winter.

A new "set"?
Do you have 2 sensors?
Did you get the same results with the new sensor(s)?
I assume the wb control box has a +5v out. Are you also using a shared SIGNAL ground?


Have not been out yet with the new pair of Bosch sensors.
Not sure on the shared signal ground,,,,,,,,,,


HEMI-ITIS has no cure.
My condition is fully BLOWN!!
Re: O/2 sensor location,where is the sweet spot??????? [Re: sr4440] #2023380
03/02/16 07:50 PM
03/02/16 07:50 PM
Joined: Dec 2007
Posts: 12,588
Great Neck,LI,new york
hemi-itis Offline OP
I Live Here
hemi-itis  Offline OP
I Live Here

Joined: Dec 2007
Posts: 12,588
Great Neck,LI,new york
Originally Posted By sr4440
Originally Posted By Crizila
Could be a wiring problem - loose / bad ground can do that.


Bit confused by this, with no volts the O2 sensor (mine) will read 10.4 AFR and with full voltage (5 volts) it will read 19.5. So if it is a loose ground, I would expect a rich reading followed by a lean spike when it reconnected (maybe?). shruggy

Joe


You might be in the same boat,,,,,,,,,,, work

2.17.16 013.jpg
Last edited by hemi-itis; 03/02/16 07:52 PM.

HEMI-ITIS has no cure.
My condition is fully BLOWN!!
Re: O/2 sensor location,where is the sweet spot??????? [Re: hemi-itis] #2024101
03/03/16 10:12 PM
03/03/16 10:12 PM
Joined: Jan 2005
Posts: 2,540
Milwaukee WI
T
TRENDZ Offline
master
TRENDZ  Offline
master
T

Joined: Jan 2005
Posts: 2,540
Milwaukee WI
Really just shooting in the dark here. I cant tell scale/ value without a ref point.
You say you have 2 sensors. I see the other sensor is showing close to the same value at the cursor time line. As a trend, are they both reading the same values? If so, I guess my bad sensor theory is out the window.
Are your sensor outputs calibrated correctly to your logger?
Many WB controllers have configurable outputs. I usually set the low voltage(rich) to .5 volts 10:1 a/f ratio. Then set my high voltage(lean) to 4.5 volts 20:1 a/f ratio.
This gives wiggle room when setting the logger/ecu input values.
There are very few instances when I see NO offset voltage between output and input readings on two separate devices.
I check the offset amount by setting the wideband controller to send out a straight line voltage, regardless of a/f ratio.
As an example...
10:1 a/f = .5 volts
20:1 a/f = .5 volts
Now your wideband should be outputting .5 volts no matter what the ratio is. Check your datalog. If the voltage doesn't read .5 volts, you need to mathematically change either the output voltage, or the read value.
Do the same with the high voltage...
10:1 a/f = 4.5 volts
20:1 a/f = 4.5 volts
Same deal. I keep that .5 volt window on the high and low side for offset changes. If you don't need the "windows" on the high or low side, you can widen the voltage swings(.2 volts-4.8 volts) to get better resolution.
The reason I asked about sensor ground commonality, is there are frequently these ground offsets. Some manufaturers dont want other devices to share, and some do.


"use it 'till it breaks, replace as needed"
Re: O/2 sensor location,where is the sweet spot??????? [Re: hemi-itis] #2024230
03/04/16 01:43 AM
03/04/16 01:43 AM
Joined: Dec 2007
Posts: 12,588
Great Neck,LI,new york
hemi-itis Offline OP
I Live Here
hemi-itis  Offline OP
I Live Here

Joined: Dec 2007
Posts: 12,588
Great Neck,LI,new york
At his point,I must verify the grounds for the o/2s and see it the new sensors give a better readout.I figure 2s or 3 passes to verify where I left off last.Then open the cut outs and see what happens.
Took a few more pics and must figure out how I want to fab the cutouts.

3.1.16 001.jpg3.1.16 004.jpg

HEMI-ITIS has no cure.
My condition is fully BLOWN!!
Re: O/2 sensor location,where is the sweet spot??????? [Re: hemi-itis] #2024646
03/04/16 08:15 PM
03/04/16 08:15 PM
Joined: Jan 2003
Posts: 8,166
Plymouth, MI
Blusmbl Offline
master
Blusmbl  Offline
master

Joined: Jan 2003
Posts: 8,166
Plymouth, MI
Listen to what Trendz wrote. Others have mentioned there is no way the car can run at 19:1 a/f under load, and both sensors are reading lean. There is likely a wiring problem, and you can start by checking the voltage being read at your data acquisition unit.