This is the plan for the tank:

1. a sump in the centre of the tank, with one-way-check valves so fuel can only go in, ensuring that the sump is as full as it can be at any time;

2. the pump pickups (2) collect fuel from this sump;

3. there is an inspection plate over the sump (centre of tank), which can be accessed through a access panel made in the trunk floor;

4. there is a pump-mounting-plate, at the front of the tank from which the two pumps will be suspended, but able to be removed, through the same trunk floor access panel for servicing of the pumps or pickup filters (2);

4. Delivery (-10 x 2) and return (-10 x 1) exit through the front of the tank & clear all axle/moving components, incuding adequate distance from exhaust.

6681992-1-FuelTank-5.jpg (68 downloads)