Quote:

What is it you are trying to achieve. Do you "need" lash caps for rocker geometry............because just using a retainer and lock to increase installed height, doesn't mean you must use lash caps. I am sure you are also aware, that if you DO use a longer valve, it will alter rocker geometry and you might have to raise shafts and get a longer pushrod to correct it. If you have proper geometry now and pushrods, the obvious choice is +.050 locks and +.050 retainers.

Monte




What Monte said about the locks and retainers...
if your trying to just increase the install height..
of course if the geometry is fine now with the valve
length you have