Hey guys, I upgraded to a stroked 512 last summer and now I'm looking to upgrade the fuel line with PTFE braided stainless. Factory lines are 5/16" supply with a 3/16" return. Motor is pretty docile with having untouched Eddie heads and a 239 @ .050" roller cam in it. Future plans include pulling the heads off for CNC porting and a 600HP FiTech - won't be going beyond that, so room for upgrades beyond this level would be unneeded.

I was thinking 3/8" supply and 1/4" return. Opinions? Thanks guys!


1987 Fifth Avenue - 512/518/D60
Re: Fuel line and return size [Re: MarkZ] #2438494
01/21/18 05:32 PM
01/21/18 05:32 PM
Joined: May 2005
Posts: 4,730
Florida
BDW Online content
master
BDW  Online Content
master

Joined: May 2005
Posts: 4,730
Florida
I'm not near your power level, but when I added the 600hp Fitech, added a 3/8" line for fuel and used the factory 5/16" for the return.

That way you're only adding 1 line.

Re: Fuel line and return size [Re: MarkZ] #2438496
01/21/18 05:33 PM
01/21/18 05:33 PM
Joined: Sep 2007
Posts: 14,889
up yours
Supercuda Offline
About to go away
Supercuda  Offline
About to go away

Joined: Sep 2007
Posts: 14,889
up yours
When I build a return system I usually use the original supply as the return and upsize the new supply. So I'd got with the 3/8" supply and use the existing 5/16" as a return. You really can't go too big on the return, within reason in case some clown want's to mwntion 2" black pipe or some such silliness.


They say there are no such thing as a stupid question.
They say there is always the exception that proves the rule.
Don't be the exception.
Re: Fuel line and return size [Re: MarkZ] #2438497
01/21/18 05:34 PM
01/21/18 05:34 PM
Joined: Jan 2003
Posts: 4,272
Morrow, OH
markz528 Offline
master
markz528  Offline
master

Joined: Jan 2003
Posts: 4,272
Morrow, OH
I would absolutely not use 1/4" retuirn. If you use 3/8 feed use the same for the return. Absolutely would make the return at least 5/16.

I am building a 69 GTX with a 505 about 700 hp. I am running 8 AN (1/2") feed and return. Aeromotive tech support agreed with these sizes.


67 Coronet 500 9.610 @ 139.20 mph
67 Coronet 500 (street car) 14.82 @ 94 mph
69 GTX (clone) - build in progress......
Re: Fuel line and return size [Re: MarkZ] #2438591
01/21/18 08:18 PM
01/21/18 08:18 PM
Joined: Aug 2011
Posts: 2,861
Pattison Texas
CSK Offline
master
CSK  Offline
master

Joined: Aug 2011
Posts: 2,861
Pattison Texas
If using a high flow,volume electric pump I would use a 3/8 supply,3/8 return, that is how my car is, 5/16 is ok for EFI, because it runs a much higher pressure, but for a carb,3/8 would be better for a return, mine is carb for now.


1968 Charger COLD A/C Hilborn EFI
512ci 9.7 compression, Stealth heads, 4.10 gear A518 ODtrans 4100lb,10.93 full street car trim
2020 T/A 392 Stock 11.79 @ 114.5

Re: Fuel line and return size [Re: MarkZ] #2438650
01/21/18 09:37 PM
01/21/18 09:37 PM
Joined: Jul 2011
Posts: 959
Chicago
PurpleBeeper Offline
super stock
PurpleBeeper  Offline
super stock

Joined: Jul 2011
Posts: 959
Chicago
I personally like the idea of using the stock 5/16" line as a fuel return. It's already there, well-routed & simple.


70 Roadrunner convt. street car 440+6, NOS, 4-spd, SS springs '96 Mustang GT convt. street car '04 4.6 SOHC, NOS, auto, lowered "Officer, that button is for short on-ramps"
Re: Fuel line and return size [Re: PurpleBeeper] #2438725
01/21/18 11:02 PM
01/21/18 11:02 PM
Joined: Jan 2007
Posts: 7,664
IN
A
ahy Offline
master
ahy  Offline
master
A

Joined: Jan 2007
Posts: 7,664
IN
On my 496 I run 3/8" supply and 5/16" return. It is EFI. Works fine. Carb style regulators may like a bigger return. IDK.

For what it is worth, I like and run stock style steel lines (mostly). Tough, cost effective and they route well in the rear which can be tough. I use braided racing hose at the ends to hook everything up.

Re: Fuel line and return size [Re: MarkZ] #2438736
01/21/18 11:11 PM
01/21/18 11:11 PM
Joined: Jan 2005
Posts: 4,421
Michigan
MarkZ Offline OP
Worthy
MarkZ  Offline OP
Worthy

Joined: Jan 2005
Posts: 4,421
Michigan
I should have stated that I plan on using an in-tank pump like the Aeromotive 340 when I change over. I'm just not a fan of the under hood surge tank FiTech sells. It'll be a another season though before that happens. Just trying to get the lines in order this year.

Thanks for the input everyone. This forum has been invaluable to me over the years.


1987 Fifth Avenue - 512/518/D60
Re: Fuel line and return size [Re: MarkZ] #2441483
01/27/18 02:06 PM
01/27/18 02:06 PM
Joined: Mar 2007
Posts: 254
Opelika, AL
J
JRs_Charger Offline
enthusiast
JRs_Charger  Offline
enthusiast
J

Joined: Mar 2007
Posts: 254
Opelika, AL
I have the 600 HP FItech, and an in tank pump, and use 3/8th line for both feed and return. The large return line seems to help keep fuel temps lower.

The 5/16 and 1/4 lines are a no go.

Re: Fuel line and return size [Re: JRs_Charger] #2441503
01/27/18 02:37 PM
01/27/18 02:37 PM
Joined: May 2005
Posts: 4,730
Florida
BDW Online content
master
BDW  Online Content
master

Joined: May 2005
Posts: 4,730
Florida
Originally Posted By JRs_Charger
I have the 600 HP FItech, and an in tank pump, and use 3/8th line for both feed and return. The large return line seems to help keep fuel temps lower.

The 5/16 and 1/4 lines are a no go.


I have exact set-up, 600 HP Fitech with Spectra tank with in tank pump.
Added 3/8" line for feed and used existing 5/16" for return. Works perfectly.

Curious why you say it's "no go"?

Nice thing about Fitech is you can adjust the voltage to the fuel pump , PWM, to lower the fuel pressure if needed.

Last edited by cnxt; 01/27/18 02:40 PM.
Re: Fuel line and return size [Re: BDW] #2441869
01/28/18 12:44 AM
01/28/18 12:44 AM
Joined: Mar 2007
Posts: 254
Opelika, AL
J
JRs_Charger Offline
enthusiast
JRs_Charger  Offline
enthusiast
J

Joined: Mar 2007
Posts: 254
Opelika, AL
I'm sorry, I meant the specific combination of 5/16 feed and 1/4 return line is a no go. That would overheat and kill the fuel pump very quickly.

Here's a helpful article where Aeromotive recommends certain line sizes for different horsepower engines.

http://www.stangtv.com/features/fuel-system-troubleshooting-killing-gremlins-with-aeromotive/







Powered by UBB.threads™ PHP Forum Software 7.7.1