I am returning my Duster to some very limited street duty - slicks, wheelie bars, alcohol, (fuel not cocktails ) etc. I'm having a custom aluminum 22 gallon fuel cell built due to the horrendous fuel mileage expected.

As to venting the cell, I've considered two -6 vents, one -6 vent, or one -8 vent. Anybody have any experience with this?

The rollover valves are fairly expensive once you include the fittings and hoses. I don't mind spending for what is needed, but I hate wasting money....


[image]http://s1126.photobucket.com/user/nhramark1/library/Racing[/image] 9.100 @ 150 mph 5.780 @ 120 mph
Re: Fuel cell vent(s)? [Re: nhramark] #1624800
05/25/14 04:59 PM
05/25/14 04:59 PM
Joined: May 2004
Posts: 12,388
Taxes & Virus's R-US, NY
Dragula Offline
I Live Here
Dragula  Offline
I Live Here

Joined: May 2004
Posts: 12,388
Taxes & Virus's R-US, NY
The amount of fuel leaving the cell is what you need to consider. I have imploded a plastic cell or two without the proper venting. If you have an AN8 leaving, then an AN8 vent should be used. If you have two AN8's leaving, then upsizing it, will be need to keep from creating a vacuum. My A1000 did a number on a plastic fuel cell of mine.


'70 Cuda,...605 EFI Hemi Street Car (6.20 best pass, 1.33 60ft)
https://www.youtube.com/watch?v=WYw6RA-k5Bk (6.25 at 108.75mph from inside car)
https://www.youtube.com/watch?v=3zQEb9uxFng (6.25 at 108mph from outside car)
https://www.youtube.com/watch?v=JCvfzsC4NgM (9.9)

'66 Barracuda AWB Stretched nose Blown 440 Car in build stage

'71 Duster Drag Car 400 Low Deck 512 best 6.002 at 115.44mph
https://www.youtube.com/watch?v=Znuo3jMUXTk
Re: Fuel cell vent(s)? [Re: Dragula] #1624801
05/25/14 07:05 PM
05/25/14 07:05 PM
Joined: Mar 2003
Posts: 9,100
Rogue River, OR
Jeremiah Offline
master
Jeremiah  Offline
master

Joined: Mar 2003
Posts: 9,100
Rogue River, OR
I run a -8 with a roll over bulkhead fitting.

http://www.summitracing.com/parts/sum-g3114/overview/

Some of them can be plumbed in line however they seem to be more expensive.

Re: Fuel cell vent(s)? [Re: nhramark] #1624802
05/25/14 10:22 PM
05/25/14 10:22 PM
Joined: Jun 2003
Posts: 52,972
Romeo MI
MR_P_BODY Offline
Master
MR_P_BODY  Offline
Master

Joined: Jun 2003
Posts: 52,972
Romeo MI
The filler cap is also vented so a single -8 is plenty

Re: Fuel cell vent(s)? [Re: MR_P_BODY] #1624803
05/26/14 12:08 PM
05/26/14 12:08 PM
Joined: Jan 2003
Posts: 3,104
Wheels up, MO
N
nhramark Offline OP
master
nhramark  Offline OP
master
N

Joined: Jan 2003
Posts: 3,104
Wheels up, MO
uh-oh, I hadn't thought about the cap. So it will be venting alcohol fumes into my trunk... where my battery sits? That's going to create new problems.


[image]http://s1126.photobucket.com/user/nhramark1/library/Racing[/image] 9.100 @ 150 mph 5.780 @ 120 mph
Re: Fuel cell vent(s)? [Re: nhramark] #1624804
05/26/14 12:40 PM
05/26/14 12:40 PM
Joined: Mar 2003
Posts: 9,100
Rogue River, OR
Jeremiah Offline
master
Jeremiah  Offline
master

Joined: Mar 2003
Posts: 9,100
Rogue River, OR
The cap on my cell is a non-vented aircraft style deal. It has a safety blow off but is not normally vented.

Re: Fuel cell vent(s)? [Re: nhramark] #1624805
05/26/14 12:41 PM
05/26/14 12:41 PM
Joined: Nov 2003
Posts: 1,839
NW Indiana
F
fbs63 Offline
top fuel
fbs63  Offline
top fuel
F

Joined: Nov 2003
Posts: 1,839
NW Indiana
Pro-Werks makes screw on replacement caps that are not vented. Use that and vent sizes equal to what you have feeding the pump and you will be good.

Re: Fuel cell vent(s)? [Re: nhramark] #1624806
05/26/14 03:46 PM
05/26/14 03:46 PM
Joined: Jun 2003
Posts: 52,972
Romeo MI
MR_P_BODY Offline
Master
MR_P_BODY  Offline
Master

Joined: Jun 2003
Posts: 52,972
Romeo MI
Quote:

uh-oh, I hadn't thought about the cap. So it will be venting alcohol fumes into my trunk... where my battery sits? That's going to create new problems.




They have a pressure and vac valve in them... if you
pump MOST of the pressure through the vent line it
wont dump thru the cap.. I forget the vac/pressure
settings are on it but its like 29-35" of water for
the pressure side and 10" of water vac... so if you
dump the pressure off on the line you wont have to
worry
EDIT
if it has a hole in the center thats in the tank it
has the valve

Last edited by MR_P_BODY; 05/26/14 03:48 PM.
Re: Fuel cell vent(s)? [Re: MR_P_BODY] #1624807
05/26/14 09:23 PM
05/26/14 09:23 PM
Joined: Oct 2003
Posts: 7,506
Az
Crizila Offline
master
Crizila  Offline
master

Joined: Oct 2003
Posts: 7,506
Az
Quote:

The filler cap is also vented so a single -8 is plenty