Previous Thread
Next Thread
Print Thread
Question about fuel cell vent line #2824898
09/25/20 11:19 AM
09/25/20 11:19 AM
Joined: Jan 2003
Posts: 4,282
Danville, NH
M
Mopar_Mike Offline OP
master
Mopar_Mike  Offline OP
master
M

Joined: Jan 2003
Posts: 4,282
Danville, NH
Installed a fuel cell in my trunk on my 67 Coronet. All is good but I smell gas. It is vented but at this time it is just a straight hose out of the tank through the trunk floor. I am going to get a longer hose so I can loop it but also wondering about a roll over valve and some sort of an attachable charcoal canister? to help stop the fumes smell. Is there such a piece that would work as both a one way valve and fume stopper? Thanks.


RS23L7 4-Speed



Re: Question about fuel cell vent line [Re: Mopar_Mike] #2824903
09/25/20 11:23 AM
09/25/20 11:23 AM
Joined: Jan 2003
Posts: 30,998
Oregon
A
AndyF Offline
I Win
AndyF  Offline
I Win
A

Joined: Jan 2003
Posts: 30,998
Oregon
The factory guys have spent a lot of time working on that issue over the last 40 years so you might just copy what they do. The vent doesn't need to be very large so that is the most common mistake that people make. Adding a canister might be the easiest first step. One thing you have to watch out for with a fuel cell is that typically they are not designed for street use so they don't have any place for the vapor. Most fuel cells have a flat top so if you fill it to the top there is no room for the vapor. There needs to be an expansion tank of some sort attached to the fuel cell if you're going to drive it on the street.

Last edited by AndyF; 09/25/20 11:26 AM.
Re: Question about fuel cell vent line [Re: Mopar_Mike] #2824999
09/25/20 02:10 PM
09/25/20 02:10 PM
Joined: Sep 2007
Posts: 876
Arizona
PolyDart Offline
super stock
PolyDart  Offline
super stock

Joined: Sep 2007
Posts: 876
Arizona
My garage stinks of fuel in the summer from non-evap controlled cars venting gasoline fumes. It's at it's worst after I've driven the car on a hot day and then park it in the garage.

Re: Question about fuel cell vent line [Re: AndyF] #2825006
09/25/20 02:31 PM
09/25/20 02:31 PM
Joined: Jan 2003
Posts: 965
Odessa, Fl
B
blowndart Offline
super stock
blowndart  Offline
super stock
B

Joined: Jan 2003
Posts: 965
Odessa, Fl
Originally Posted by AndyF
The vent doesn't need to be very large so that is the most common mistake that people make.


The vent line needs to be large enough to allow the same volume of air to enter the tank as the volume of fuel that leaves the tank and goes to the engine (minus whatever is returned if you have a fuel return system). Otherwise you will have fuel delivery problems.

What I did to resolve the issue on my fuel cell was to run the vent line to a tee fitting. On one side of the tee fitting is a check valve that lets air into the tank to compensate for the volume of the fuel that is pumped out of the tank when running but not let vapors out. On the other side of the tee is an adjustable pressure relief valve so that the vapor has to build up a little pressure before it can be released. It’s set at a pretty low pressure setting so the fuel cell doesn’t become much of an expansion tank, which it’s not designed to be. After doing that, no more gas smell in my garage.

Re: Question about fuel cell vent line [Re: blowndart] #2825019
09/25/20 03:23 PM
09/25/20 03:23 PM
Joined: Sep 2003
Posts: 19,355
north of coder
moparx Offline
"Butt Crack Bob"
moparx  Offline
"Butt Crack Bob"

Joined: Sep 2003
Posts: 19,355
north of coder
where did you "exhaust" the pressure side of the T fitting to ?
TIA.
beer

Re: Question about fuel cell vent line [Re: moparx] #2825033
09/25/20 03:42 PM
09/25/20 03:42 PM
Joined: Jan 2003
Posts: 965
Odessa, Fl
B
blowndart Offline
super stock
blowndart  Offline
super stock
B

Joined: Jan 2003
Posts: 965
Odessa, Fl
It's just vented below the fuel cell. On the outside of the car, obviously.

Re: Question about fuel cell vent line [Re: Mopar_Mike] #2825040
09/25/20 03:52 PM
09/25/20 03:52 PM
Joined: Dec 2003
Posts: 22,696
Bitopia
J
jcc Offline
If you can't dazzle em with diamonds..
jcc  Offline
If you can't dazzle em with diamonds..
J

Joined: Dec 2003
Posts: 22,696
Bitopia
So the problem really is, how are gas fumes getting to the drivers nose?
Is the problem when driving, or sitting still or both?
Seems figuring this detail out would help get the vent located into a moving air stream that does not recirculate fumes back to the car when in motion, which so much of the air does at the rear,


Reality check, that half the population is smarter then 50% of the people and it's a constantly contested fact.
Re: Question about fuel cell vent line [Re: jcc] #2825045
09/25/20 04:13 PM
09/25/20 04:13 PM
Joined: Sep 2008
Posts: 656
Florida
CJD AUTOMOTIVE Offline
mopar
CJD AUTOMOTIVE  Offline
mopar

Joined: Sep 2008
Posts: 656
Florida
You can do the junkyard crawl and grab a canister, vent valve, and purge solenoid from an older Ram or Caravan. The vent valve is the one way valve (it will have a filter as well). The fumes will accumulate in the canister. If you hook up the purge solenoid, one line goes to the canister and the other to engine vacuum. The solenoid is 12 volt, so hook it to a switch. When you start the car, flip the switch and purge the canister for a few minutes to clear it of the previously stored vapor.


Craig Scholl
CJD Automotive, LLC
Jacksonville, FL
www.CJDAUTOMOTIVE.com
904-400-1802

"I own a Mopar. I already know it won't be in stock, won't ship tomorrow, and won't fit without modification"
Re: Question about fuel cell vent line [Re: blowndart] #2825046
09/25/20 04:20 PM
09/25/20 04:20 PM
Joined: Apr 2006
Posts: 4,220
West Plains, MO
DrCharles Offline
master
DrCharles  Offline
master

Joined: Apr 2006
Posts: 4,220
West Plains, MO
Originally Posted by blowndart
What I did to resolve the issue on my fuel cell was to run the vent line to a tee fitting. On one side of the tee fitting is a check valve that lets air into the tank to compensate for the volume of the fuel that is pumped out of the tank when running but not let vapors out. On the other side of the tee is an adjustable pressure relief valve so that the vapor has to build up a little pressure before it can be released. It’s set at a pretty low pressure setting so the fuel cell doesn’t become much of an expansion tank, which it’s not designed to be. After doing that, no more gas smell in my garage.


This sounds interesting. I just ran an aluminum fuel line vertically a few inches, made a u-turn and back out through the floor of the car. No gas smell in the garage that I've noticed.
But I like your idea better. What parts did you use for the check valve and pressure relief?

Re: Question about fuel cell vent line [Re: AndyF] #2825053
09/25/20 04:32 PM
09/25/20 04:32 PM
Joined: Jul 2004
Posts: 19,317
State of confusion
T
Thumperdart Offline
I Live Here
Thumperdart  Offline
I Live Here
T

Joined: Jul 2004
Posts: 19,317
State of confusion
The bigger the electric fuel pump, the bigger the vent needs to be from what I've seen and a customer of mine Shane Studly races a wagon w/a stock gas tank and an elec. pump and it crushed the brass float we USED to run from not enuff pressure escape/ventilation. He vented the fill neck, and problem solved and it actually filled his crank case full of gas on the way home from a race before he vented it. I plugged mine once and the pressure went past my pump and straight into my carb.....


72 Dart 470 n/a BB stroker street car `THUMPER`...Check me out on FB Dominic Thumper for videos and lots of carb pics......760-900-3895.....
Re: Question about fuel cell vent line [Re: DrCharles] #2825071
09/25/20 05:25 PM
09/25/20 05:25 PM
Joined: Jan 2003
Posts: 965
Odessa, Fl
B
blowndart Offline
super stock
blowndart  Offline
super stock
B

Joined: Jan 2003
Posts: 965
Odessa, Fl
Originally Posted by DrCharles
Originally Posted by blowndart
What I did to resolve the issue on my fuel cell was to run the vent line to a tee fitting. On one side of the tee fitting is a check valve that lets air into the tank to compensate for the volume of the fuel that is pumped out of the tank when running but not let vapors out. On the other side of the tee is an adjustable pressure relief valve so that the vapor has to build up a little pressure before it can be released. It’s set at a pretty low pressure setting so the fuel cell doesn’t become much of an expansion tank, which it’s not designed to be. After doing that, no more gas smell in my garage.


This sounds interesting. I just ran an aluminum fuel line vertically a few inches, made a u-turn and back out through the floor of the car. No gas smell in the garage that I've noticed.
But I like your idea better. What parts did you use for the check valve and pressure relief?

Mine was originally ran this way, down to a charcoal filter. The fumes were overpowering when I walked into my garage. After changing to the PRV and check valve setup, no more fumes.

The pressure relief valve is very similar to this one, but I think the range on mine is 0-15 or 20 PSI. It's currently set for somewhere between 1 & 2 PSI.
https://www.ebay.com/itm/0-100-PSI-Brass-CR-Series-Adjustable-Air-Pressure-Relief-Valve-Control-Devices/291696721009?_trkparms=aid%3D1110009%26algo%3DSPLICE.COMPLISTINGS%26ao%3D1%26asc%3D20200220094952%26meid%3D69b80d3bf80e4e23b3c577c6c1034a27%26pid%3D100008%26rk%3D1%26rkt%3D12%26mehot%3Dpp%26sd%3D113207571600%26itm%3D291696721009%26pmt%3D1%26noa%3D0%26pg%3D2047675%26algv%3Ddefault&_trksid=p2047675.c100008.m2219

The check valve was some used fuel check valve with 8 AN fittings from a person that sold used aviation parts off eBay. Any check valve made for fuels that stays closed, one way, even with no backpressure, will work.

I've had this on my car for about 8-10 years now. No problems.

Re: Question about fuel cell vent line [Re: blowndart] #2825077
09/25/20 05:34 PM
09/25/20 05:34 PM
Joined: Jan 2003
Posts: 30,998
Oregon
A
AndyF Offline
I Win
AndyF  Offline
I Win
A

Joined: Jan 2003
Posts: 30,998
Oregon
Originally Posted by blowndart
Originally Posted by AndyF
The vent doesn't need to be very large so that is the most common mistake that people make.


The vent line needs to be large enough to allow the same volume of air to enter the tank as the volume of fuel that leaves the tank and goes to the engine (minus whatever is returned if you have a fuel return system). Otherwise you will have fuel delivery problems.




That is true but the vent line can be much smaller than the fuel line size. Fuel cells often come with a #8 vent line but the vent line doesn't need to be anywhere near that size. 1/4 inch vacuum line should be fine.

Re: Question about fuel cell vent line [Re: Mopar_Mike] #2825081
09/25/20 06:00 PM
09/25/20 06:00 PM
Joined: Oct 2010
Posts: 2,406
Ambridge, Pa.
R
rickraw Offline
top fuel
rickraw  Offline
top fuel
R

Joined: Oct 2010
Posts: 2,406
Ambridge, Pa.
As Andy stated, rollover valve, #8 hose not looped but an arch. A loop can act like at trap if fuel gets in it and it won’t vent right. I ran my vent to the rear of the car. I put a piece of scotch pad in an old Russell fuel filter, vents fine, no fumes in the garage.

Re: Question about fuel cell vent line [Re: blowndart] #2825292
09/26/20 12:29 PM
09/26/20 12:29 PM
Joined: Sep 2003
Posts: 19,355
north of coder
moparx Offline
"Butt Crack Bob"
moparx  Offline
"Butt Crack Bob"

Joined: Sep 2003
Posts: 19,355
north of coder

Re: Question about fuel cell vent line [Re: moparx] #2825330
09/26/20 02:02 PM
09/26/20 02:02 PM
Joined: Apr 2006
Posts: 4,220
West Plains, MO
DrCharles Offline
master
DrCharles  Offline
master

Joined: Apr 2006
Posts: 4,220
West Plains, MO
It may be hard to set a 0-100 psi valve to just 1 or 2 psi... a 0-20 or 0-10 would be much better. If there is one available wink

Re: Question about fuel cell vent line [Re: DrCharles] #2825332
09/26/20 02:12 PM
09/26/20 02:12 PM
Joined: Mar 2011
Posts: 3,069
Michigan
A
A727Tflite Offline
master
A727Tflite  Offline
master
A

Joined: Mar 2011
Posts: 3,069
Michigan
If you vent under the car do what Chrysler did on some cars - place the vent opening inside the rear longitudinal.

Re: Question about fuel cell vent line [Re: DrCharles] #2825388
09/26/20 06:13 PM
09/26/20 06:13 PM
Joined: Jan 2003
Posts: 965
Odessa, Fl
B
blowndart Offline
super stock
blowndart  Offline
super stock
B

Joined: Jan 2003
Posts: 965
Odessa, Fl
Originally Posted by DrCharles
It may be hard to set a 0-100 psi valve to just 1 or 2 psi... a 0-20 or 0-10 would be much better. If there is one available wink


iagree







Powered by UBB.threads™ PHP Forum Software 7.7.1