Previous Thread
Next Thread
Print Thread
Home generator enclosure ??? #2803824
08/01/20 05:29 PM
08/01/20 05:29 PM
Joined: Jan 2003
Posts: 20,751
A collage of whims
topside Offline OP
Too Many Posts
topside  Offline OP
Too Many Posts

Joined: Jan 2003
Posts: 20,751
A collage of whims
I bought a 9000-watt generator for when we lose electrical power in winter, mainly just to keep heat & lights on.
It'll live on my back porch, under a carport, but still subject to blowing snow.
I'm thinking an enclosure is a good idea, not too tight (see BB in A-body laugh2) with a vented side(s) & hinged or removable lid.
(Home's already wired/boxed).

Am I over-thinking this ?
Any suggestions before I craft another monument hammer ?

Re: Home generator enclosure ??? [Re: topside] #2803828
08/01/20 05:35 PM
08/01/20 05:35 PM
Joined: Jan 2003
Posts: 32,922
Grand Prairie,Texas
stumpy Online content
I Win
stumpy  Online Content
I Win

Joined: Jan 2003
Posts: 32,922
Grand Prairie,Texas
It wouldn't hurt and be sure to vent the exhaust fumes out of the carport so they won't collect and smoke you out.

Re: Home generator enclosure ??? [Re: stumpy] #2803914
08/01/20 07:50 PM
08/01/20 07:50 PM
Joined: Oct 2003
Posts: 2,331
Banana Republic
FM3AAR Offline
top fuel
FM3AAR  Offline
top fuel

Joined: Oct 2003
Posts: 2,331
Banana Republic
Consider keeping mice out when not running.


“You’ll own nothing” — And “you’ll be happy about it.”
K. Schwab



Re: Home generator enclosure ??? [Re: FM3AAR] #2803922
08/01/20 08:03 PM
08/01/20 08:03 PM
Joined: Jan 2003
Posts: 20,751
A collage of whims
topside Offline OP
Too Many Posts
topside  Offline OP
Too Many Posts

Joined: Jan 2003
Posts: 20,751
A collage of whims
Yeah, some kind of tailpipe extension would be a good idea, and yes, the box would also keep the field mice away.
Probably gonna shop those garden enclosures, see if that'll work.
Finding a power cord is proving to be, um, interesting. I only need 10-12 feet, which is apparently ultra-rare.
May be better to have my electrician fab one up.

Re: Home generator enclosure ??? [Re: topside] #2803926
08/01/20 08:12 PM
08/01/20 08:12 PM
Joined: Jan 2003
Posts: 2,331
Addison Twp, Mi.
RobG Offline
top fuel
RobG  Offline
top fuel

Joined: Jan 2003
Posts: 2,331
Addison Twp, Mi.
Make sure you elevate it a few inches to keep it out of water puddles. When inside the structure, keep the exhaust off of wood. I have seen hot exhaust catch siding on fire.. Make sure snow does not build up around it.


I am not rich...but I get off my ass everyday to make sure I am not broke!

Can we get the Mexican cartels to help us with our supply chain issues? They don't seem to have any trouble getting stuff from one place to another.
Re: Home generator enclosure ??? [Re: RobG] #2803936
08/01/20 08:28 PM
08/01/20 08:28 PM
Joined: Jan 2003
Posts: 20,751
A collage of whims
topside Offline OP
Too Many Posts
topside  Offline OP
Too Many Posts

Joined: Jan 2003
Posts: 20,751
A collage of whims
The porch is raised, about 6".
Carport is open on 3 sides, plenty of air & breeze.
Definitely will pay attention to heat & exhaust output.

Re: Home generator enclosure ??? [Re: topside] #2803937
08/01/20 08:31 PM
08/01/20 08:31 PM
Joined: Dec 2003
Posts: 22,696
Bitopia
J
jcc Offline
If you can't dazzle em with diamonds..
jcc  Offline
If you can't dazzle em with diamonds..
J

Joined: Dec 2003
Posts: 22,696
Bitopia
What fuel? I would be hesitant to have a liquid/gas fueled genset on or near any flammable occupied structure or flooring. I have a lot of experience with gensets near people, and the exhaust fumes are seldom predictable, and of course potentially very deadly. An interior carbon monoxide detector would be a nice addition.

Last edited by jcc; 08/01/20 08:32 PM.

Reality check, that half the population is smarter then 50% of the people and it's a constantly contested fact.
Re: Home generator enclosure ??? [Re: jcc] #2803940
08/01/20 08:37 PM
08/01/20 08:37 PM
Joined: Aug 2019
Posts: 9,432
Super Spudsville
Mr PotatoHead Offline
Half Baked
Mr PotatoHead  Offline
Half Baked

Joined: Aug 2019
Posts: 9,432
Super Spudsville
What fuel? I would be hesitant to have a liquid/gas fueled genset on or near any flammable occupied structure or flooring.

Thats like being afraid to park your car in a garage.

I keep a 7k unit full inside my back mud room, when needed roll it out on the raised back porch with the ex facing out.

Still here after 15 years doing so.

I swap the gas out yearly and inspect fuel line, ect.


STOP POTATO HATE!
Re: Home generator enclosure ??? [Re: Mr PotatoHead] #2803946
08/01/20 08:41 PM
08/01/20 08:41 PM
Joined: Dec 2003
Posts: 22,696
Bitopia
J
jcc Offline
If you can't dazzle em with diamonds..
jcc  Offline
If you can't dazzle em with diamonds..
J

Joined: Dec 2003
Posts: 22,696
Bitopia
Originally Posted by Mr. Potatohead
What fuel? I would be hesitant to have a liquid/gas fueled genset on or near any flammable occupied structure or flooring.

Thats like being afraid to park your car in a garage.

I keep a 7k unit full inside my back mud room, when needed roll it out on the raised back porch with the ex facing out.

Still here after 15 years doing so.

I swap the gas out yearly and inspect fuel line, ect.



I don't fuel my car in a power outage in my garage in the middle of the night when its running or hot and the family sleeping inside, but be my guest.

Last edited by jcc; 08/01/20 08:42 PM.

Reality check, that half the population is smarter then 50% of the people and it's a constantly contested fact.
Re: Home generator enclosure ??? [Re: jcc] #2803987
08/01/20 10:15 PM
08/01/20 10:15 PM
Joined: Jul 2006
Posts: 1,294
New Jersey
P
Powerflow Offline
pro stock
Powerflow  Offline
pro stock
P

Joined: Jul 2006
Posts: 1,294
New Jersey
Check with the building department in your area for regulations concerning generators installed in/on/near wooden structures. The generator is noisy and that may be amplified near a building. I'd also look into vibration isolator pads to dampen vibration near the unit.

Re: Home generator enclosure ??? [Re: Powerflow] #2803992
08/01/20 10:43 PM
08/01/20 10:43 PM
Joined: Feb 2003
Posts: 3,665
NE OHIO
K
kevin69bman Offline
master
kevin69bman  Offline
master
K

Joined: Feb 2003
Posts: 3,665
NE OHIO
OK
So its a not a whole house unit right?
So how are you hooking up every thing? That you cant find a rubber 10/4 cord ? to run 30 amp as that's all the breaker on the unit will do?
Are you wanting to keep it out side all the time? Or are trying to cut the noise down when running it?

Last edited by kevin69bman; 08/01/20 11:00 PM.
Re: Home generator enclosure ??? [Re: kevin69bman] #2804001
08/01/20 11:23 PM
08/01/20 11:23 PM
Joined: Jan 2003
Posts: 20,751
A collage of whims
topside Offline OP
Too Many Posts
topside  Offline OP
Too Many Posts

Joined: Jan 2003
Posts: 20,751
A collage of whims
Gasoline power.
Mainly just to keep heat & well pump on, though a few lights will fit into that output.
I'm not that concerned with noise in comparison to that, nor running everything I own.
I'm very careful about gasoline, unit holds enough to run 12 hours or so, would not fill it when hot or running.
Everything here is wood, live in a forest, so fire prevention is a religion.
I plan on adding/using metal near hot surfaces & dealing with exhaust.
I see some plastic garden-style enclosures, reluctant to do that.
Location partially driven by snow from shoveling roof, partially by exposure, partially by keeping cord length down (efficiency).
I handled the cord about an hour ago.

Re: Home generator enclosure ??? [Re: topside] #2804050
08/02/20 08:01 AM
08/02/20 08:01 AM
Joined: Jan 2006
Posts: 8,162
USA
3
360view Offline
Moparts resident spammer
360view  Offline
Moparts resident spammer
3

Joined: Jan 2006
Posts: 8,162
USA
This youtube clip is a segment of a “This Old House” episode where they demonstrate the installation of an interesting kit for using portable generators with house electrical systems

https://www.youtube.com/watch?v=d9V4RjzUXV8

Also check out this device that goes between your electric company meter and house wiring to connect a generator available at Home Depot

https://www.homedepot.com/p/GenerLink-30-Amp-Meter-Mounted-Transfer-Switch-MA23-N/301961623

For sound reduction,
check out “Sonex” waffle surfaced foam,

https://sonex-online.com/

and the pre-fabricated sound reduction fences
made for Outdoor air conditioning units

Re: Home generator enclosure ??? [Re: 360view] #2804060
08/02/20 09:01 AM
08/02/20 09:01 AM
Joined: Dec 2003
Posts: 5,646
Port Huron, Michigan
MI_Custumz Offline
master
MI_Custumz  Offline
master

Joined: Dec 2003
Posts: 5,646
Port Huron, Michigan
We left our portable in the shed. When we hooked it up, we placed it on a flat spot and put a deck table umbrella through some zip ties on the handle to keep rain off it from above. Still got wet from the side, but was looking at an enclosure. I have seen some around that look like a mini shed and are used for trash cans. Keeps the critters out, top lifts for access to put trash in and sides fold out to get cans out. Maybe something like that would work? You don't want to keep it totally enclosed when running so some blowing rain will get in no matter what you do. We have since upgraded to a whole house one and love it.

Re: Home generator enclosure ??? [Re: topside] #2804067
08/02/20 09:11 AM
08/02/20 09:11 AM
Joined: Jan 2003
Posts: 2,331
Addison Twp, Mi.
RobG Offline
top fuel
RobG  Offline
top fuel

Joined: Jan 2003
Posts: 2,331
Addison Twp, Mi.
I live in the country in an area that on average losses power 6 times a year. Trees falling on lines, 50 year old transformers blowing, dogs pissing on telephone poles....no power.

I use to back feed into the box with a gas generator like yours. The best thing I did was install a Generac generator 2 years ago. It is plummed into the natural gas line. There are propane versions. 11K Kw powers 70$ of my home. Easy payment/financing thru Generac. No more refueling in 20 degree weather.


I am not rich...but I get off my ass everyday to make sure I am not broke!

Can we get the Mexican cartels to help us with our supply chain issues? They don't seem to have any trouble getting stuff from one place to another.
Re: Home generator enclosure ??? [Re: RobG] #2804254
08/02/20 02:30 PM
08/02/20 02:30 PM
Joined: Dec 2003
Posts: 5,646
Port Huron, Michigan
MI_Custumz Offline
master
MI_Custumz  Offline
master

Joined: Dec 2003
Posts: 5,646
Port Huron, Michigan
I got a 10% Veteran discount at Home Depot and 2 years at 0% with their credit card when we got ours.

Re: Home generator enclosure ??? [Re: 360view] #2804279
08/02/20 03:39 PM
08/02/20 03:39 PM
Joined: Jan 2003
Posts: 4,142
Canada -- Posts: 4034 -Registe...
5
5thAve Offline
Doesn't care what this says anyway
5thAve  Offline
Doesn't care what this says anyway
5

Joined: Jan 2003
Posts: 4,142
Canada -- Posts: 4034 -Registe...
Originally Posted by 360view
This youtube clip is a segment of a “This Old House” episode where they demonstrate the installation of an interesting kit for using portable generators with house electrical systems

https://www.youtube.com/watch?v=d9V4RjzUXV8

Also check out this device that goes between your electric company meter and house wiring to connect a generator available at Home Depot

https://www.homedepot.com/p/GenerLink-30-Amp-Meter-Mounted-Transfer-Switch-MA23-N/301961623

For sound reduction,
check out “Sonex” waffle surfaced foam,

https://sonex-online.com/

and the pre-fabricated sound reduction fences
made for Outdoor air conditioning units


You're supposed to use some sort of transfer switch when using a generator to prevent it from back feeding into the lines and killing someone.

For a generator enclosure you're best off to either cover it with an old car cover or something else or make some sort of light crate that you can take off it when you need it. Portable generators aren't meant to be run in an enclose so having it inside one when it's in use could damage it frmo the heat and fumes. It's meant to hold up to the weather anyway so it sohuldn't be a problem being exposed when it's running.