Re: Ammeter Pegged...Burning Electrical Smell
[Re: 70gtx440dana]
#1205005
03/28/12 04:22 PM
03/28/12 04:22 PM
|
Joined: Nov 2004
Posts: 9,316 SoCal
68HemiB
master
|
master
Joined: Nov 2004
Posts: 9,316
SoCal
|
What he said. Yes, running all the load through the ammeter was a less than clever design, and the suggested bypass is seen by most as a good idea. HOWEVER, the pegged ammeter at hand is an indication that something else is very wrong. This must be addressed immediately!
Down to just a blue car now.
|
|
|
Re: Ammeter Pegged...Burning Electrical Smell
[Re: 68HemiB]
#1205006
03/28/12 04:37 PM
03/28/12 04:37 PM
|
Joined: Nov 2003
Posts: 36,041 Lincoln Nebraska
RapidRobert
Circle Track
|
Circle Track
Joined: Nov 2003
Posts: 36,041
Lincoln Nebraska
|
bad voltage reg EDIT pull the triangle VR connector ASAP so it ain't charging. It is far better to deep cycle (run it down then charge it up) the battery a time or 2 till you solve it rather than having the system full fielded like it is now, as said very dangerous
Last edited by RapidRobert; 03/28/12 09:53 PM.
|
|
|
Re: Ammeter Pegged...Burning Electrical Smell
[Re: RapidRobert]
#1205007
03/28/12 10:58 PM
03/28/12 10:58 PM
|
Joined: Jan 2003
Posts: 27,421 Balt. Md
383man
Too Many Posts
|
Too Many Posts
Joined: Jan 2003
Posts: 27,421
Balt. Md
|
First thing to do is find the problem for overcharging and fix it. Ron
Last edited by 383man; 03/28/12 10:58 PM.
|
|
|
Re: Ammeter Pegged...Burning Electrical Smell
[Re: GO_Fish]
#1205009
03/29/12 07:39 AM
03/29/12 07:39 AM
|
Joined: Oct 2007
Posts: 288 Birmingham, England
Mick70RR
enthusiast
|
enthusiast
Joined: Oct 2007
Posts: 288
Birmingham, England
|
This happened to me on Monday driving to work. The voltage regulator had burned out. Picked up another reg and was back on the road a few hours later.
1970 Road Runner
505 cid
MCH CNC ported Stealth heads
MP 528 camshaft
4 speed
GV overdrive