I would have that distributer put in a distributer machine and have it set up. It doesn't cost that much to have it set up and you will be able to set it up so its all in by 3000 rpm's. Total mechanical timing should be between 32 and 38 degrees typically. Total mechanical is your initial setting plus your mechanical advance. After the mechanical is set then you can adjust the vacuum advance, if you have and adjustable can.