I've got a Mallory 140 electric fuel pump I
want to reuse.

I bought AN fittings to use, but they only
thread in about two threads....what am I doing
wrong? Do I need to go back to brass fittings
for the pump?


Phil Saran Parker, Colorado
Re: Fuel pump vs AN fittings [Re: Phil Saran] #221390
02/11/09 07:43 PM
02/11/09 07:43 PM
Joined: Jun 2003
Posts: 52,972
Romeo MI
MR_P_BODY Offline
Master
MR_P_BODY  Offline
Master

Joined: Jun 2003
Posts: 52,972
Romeo MI
I'm sure the pump will have pipe thread and you might
be trying to screw in AN thread... you need AN to pipe

Re: Fuel pump vs AN fittings [Re: Phil Saran] #221391
02/11/09 07:47 PM
02/11/09 07:47 PM
Joined: Oct 2004
Posts: 5,618
long island NY
A
Ari440 Offline
master
Ari440  Offline
master
A

Joined: Oct 2004
Posts: 5,618
long island NY
they migth not be 3/8 pipe thread but 3/8 thread with a O ring


had the same problem on a barry grant 4 port regulater


I went to a local speed shop and got the rigth ones


1.39 9.85 - 137 mph
Re: Fuel pump vs AN fittings [Re: Phil Saran] #221392
02/11/09 07:59 PM
02/11/09 07:59 PM
Joined: Jun 2003
Posts: 52,972
Romeo MI
MR_P_BODY Offline
Master
MR_P_BODY  Offline
Master

Joined: Jun 2003
Posts: 52,972
Romeo MI
I just looked at their web site and they state it
uses a 3/8 pipe into/ out of the pump so you need
AN to 3/8 pipe (what ever size AN you want)

Re: Fuel pump vs AN fittings [Re: MR_P_BODY] #221393
02/11/09 08:35 PM
02/11/09 08:35 PM
Joined: Nov 2006
Posts: 396
California, USA
P
Phil Saran Offline OP
enthusiast
Phil Saran  Offline OP
enthusiast
P

Joined: Nov 2006
Posts: 396
California, USA
Mike,

These are Russell blue AN/pipe thread adapters
to fit braided fuel line to each item.

Just wondering is there a fine/corse thread
situation here??


Phil Saran Parker, Colorado
Re: Fuel pump vs AN fittings [Re: Phil Saran] #221394
02/11/09 08:44 PM
02/11/09 08:44 PM
Joined: Jul 2003
Posts: 2,637
Western Michigan
68Fastback Offline
master
68Fastback  Offline
master

Joined: Jul 2003
Posts: 2,637
Western Michigan
Phil take a run over to Home Depot with the pump and try some pipe fittings should be 3/8" NPT.

Re: Fuel pump vs AN fittings [Re: Phil Saran] #221395
02/11/09 08:47 PM
02/11/09 08:47 PM
Joined: Jun 2003
Posts: 52,972
Romeo MI
MR_P_BODY Offline
Master
MR_P_BODY  Offline
Master

Joined: Jun 2003
Posts: 52,972
Romeo MI
Pipe is pipe BUT I have seen pipe thread being under
size or over size, pipe thread is a tapered thread
and I have seen some of the alum fittings being over
sized (no clue why unless they want them beefier)
When I say pipe thread, I am referring to NPT which is
what Mallory stated 3/8 NPT

Re: Fuel pump vs AN fittings [Re: MR_P_BODY] #221396
02/11/09 09:58 PM
02/11/09 09:58 PM
Joined: Apr 2005
Posts: 12,271
Overpriced Housing Central
RobX4406 Offline
I Live Here
RobX4406  Offline
I Live Here

Joined: Apr 2005
Posts: 12,271
Overpriced Housing Central
Phil,

I got one on the desk in front of me. They are 3/8 pipe thread unless something has changed.

Re: Fuel pump vs AN fittings [Re: RobX4406] #221397
02/11/09 10:28 PM
02/11/09 10:28 PM
Joined: Nov 2006
Posts: 396
California, USA
P
Phil Saran Offline OP
enthusiast
Phil Saran  Offline OP
enthusiast
P

Joined: Nov 2006
Posts: 396
California, USA
I'll take a trip over to Home Depot tomorrow
and compare fittings.

I have to assume since I have aluminum AN/pipe
fittings, that the pipe part is oversize for
the 3/8" hole size.


Phil Saran Parker, Colorado
Re: Fuel pump vs AN fittings [Re: Phil Saran] #221398
02/11/09 11:21 PM
02/11/09 11:21 PM
Joined: Jan 2003
Posts: 5,875
communist bloc of new jersey
J
jamesc Offline
master
jamesc  Offline
master
J

Joined: Jan 2003
Posts: 5,875
communist bloc of new jersey
the comp 140 takes 3/8 pipe thread the comp 250 takes -8 AN thread. pipe thread is tapered, AN is straight and requires an O ring to seal. if you have a straight AN thread you're trying to use in the pump you have the wrong fitting. what are you trying to connect the pump to? braided hose with a fitting, aluminum line with a flare or just plain hose?

Re: Fuel pump vs AN fittings [Re: jamesc] #221399
02/11/09 11:25 PM
02/11/09 11:25 PM
Joined: Nov 2006
Posts: 396
California, USA
P
Phil Saran Offline OP
enthusiast
Phil Saran  Offline OP
enthusiast
P

Joined: Nov 2006
Posts: 396
California, USA
I've got a fuel cell with a -10AN fitting coming
out that will have braided line to a fuel filter
with -10AN on both ends to the fuel pump and then
on to a braided line to connect to 1/2" aluminum
fuel line with -8AN on each end to the fuel regulator, then -8 to the DP carb fittings.


Phil Saran Parker, Colorado
Re: Fuel pump vs AN fittings [Re: Phil Saran] #221400
02/11/09 11:32 PM
02/11/09 11:32 PM
Joined: Jan 2003
Posts: 5,875
communist bloc of new jersey
J
jamesc Offline
master
jamesc  Offline
master
J

Joined: Jan 2003
Posts: 5,875
communist bloc of new jersey
if i'm to understand you correctly the suction side of the pump needs to connect to a -10 and the discharge needs to connect to a -8 if that is the case you need these

3/8 pipe to -10

3/8 pipe to -8

Re: Fuel pump vs AN fittings [Re: Phil Saran] #221401
02/12/09 12:57 AM
02/12/09 12:57 AM
Joined: Jul 2003
Posts: 2,637
Western Michigan
68Fastback Offline
master
68Fastback  Offline
master

Joined: Jul 2003
Posts: 2,637
Western Michigan
Phil you can always hit TMR or Fast Eddies by my place for AN stuff.

Re: Fuel pump vs AN fittings [Re: 68Fastback] #221402
02/12/09 02:35 AM
02/12/09 02:35 AM
Joined: Nov 2006
Posts: 396
California, USA
P
Phil Saran Offline OP
enthusiast
Phil Saran  Offline OP
enthusiast
P

Joined: Nov 2006
Posts: 396
California, USA
Jim,

You are correct and those are the fittings I aleady bought, but the 3/8" pipe thread side
does not screw into the pump, so I will go to
Home Depot tomorrow and play around with the
brass bittings and see if I can come up with
some stuff that will work.


Phil Saran Parker, Colorado
Re: Fuel pump vs AN fittings [Re: Phil Saran] #221403
02/12/09 02:42 AM
02/12/09 02:42 AM
Joined: Jan 2003
Posts: 5,875
communist bloc of new jersey
J
jamesc Offline
master
jamesc  Offline
master
J

Joined: Jan 2003
Posts: 5,875
communist bloc of new jersey
sometimes aluminum threads can gall when threading aluminum into aluminum and once it starts it can get pretty bad. if you have those fittings afaik you have the correct fittings. look at the threads on the fitting and in the pump to see if they're buggered up any. you can chase the pump threads with a pipe tap but if the fitting threads are galled that's another problem. it's a good idea to use teflon tape or teflon thread sealant on something like this to help keep the threads from galling. i doubt HD has anything that will work correctly i believe the angle of the flare is different.

Re: Fuel pump vs AN fittings [Re: Phil Saran] #221404
02/12/09 07:30 AM
02/12/09 07:30 AM
Joined: Feb 2005
Posts: 4,316
Prospect, PA
BSB67 Offline
master
BSB67  Offline
master

Joined: Feb 2005
Posts: 4,316
Prospect, PA
My 3/8 NPT-AN fitting did not fit but a couple of threads into the 140 pump body. I used teflon pipe sealant and tightened it up and it has been fine. If you use 3/8 to conventional flare (Home Depot stuff), you'll need to then convert from the 45 to 37 degree flare.

Re: Fuel pump vs AN fittings [Re: BSB67] #221405
02/12/09 09:01 PM
02/12/09 09:01 PM
Joined: Nov 2006
Posts: 396
California, USA
P
Phil Saran Offline OP
enthusiast
Phil Saran  Offline OP
enthusiast
P

Joined: Nov 2006
Posts: 396
California, USA
The problem is that the threads on the output
side of the pump is buggered up and yes I will
need to get a pipe tape to clean it up and then
use a new aluminum AN/pipe fitting.

Thanks for all the help.