1-ga positive all the way forward. 1-ga negative through the floor & bolted to the frame. Then 4-ga from that same point forward to the block, with a strap from that bolt back to the firewall stock location.
Charge wire from the alternator is IIRC 10 ga routed to the switched side of the battery cutoff. Switch is a summit 250 amp.


LemonWedge - Street heavy / Strip ready - 11.07 @ 120