It may not be correct but I always set the gauge (dual gauge) to 100, connect it to the cylinder that is at TDC and bring it back up to 100 psi.

It makes the math easy on the leakdown percentage.

Sometimes I do have to trip the compressor to get back up to over 100 psi.

Probably the most important is that I do it the same way and record the results.