Quote:

so then I unplugged one field wire at a time and on the second wire it finally quit charging. Any way I would like to figure out what failed>


unplugging 1 field wire will disable the alt so for both to need to be unplugged it's shorted inside. Check both brushes/holders then mark the alt case so you can easily reclock it to the same position on reassembly & open it up & see what you see. Check rotor continuity to ground/any obvious improper grounds


live every 24 hour block of time like it's your last day on earth