RH will shift fully auto 1,2,3.

RE will launch in 3rd with electronics dead since in default the governor solenoid is not being modulated ( so you develop full governor pressure ) so if you pull it in manual low it should launch in 1st then you can upshift manually.

Not the greatest for control but if it hits the fan you can get home.