Take off both field wires from the alt. Jump either male alt field terminal to ground. With eng at a fast idle and your voltmeter connected to the alt batt stud then jump from the batt positive post to the other alt male field terminal for 3 seconds MAX & see (& post) what you get for voltage


live every 24 hour block of time like it's your last day on earth