Re: b body charging system.. [Re: IMGTX] #2823718
09/22/20 05:24 PM
09/22/20 05:24 PM
Joined: Aug 2007
Posts: 6,089
Valencia, España
NachoRT74 Offline
master
NachoRT74  Offline
master

Joined: Aug 2007
Posts: 6,089
Valencia, España
just like a bulb... will read ground on either terminal because the filament makes the bridge. A bulb is not more than a controled short to become it on a light source thanks to oxigen absence to burn it out like it was a complete short to burn. Well, an alt is more less the same, with the rotor just like the filament in a bulb

Last edited by NachoRT74; 09/22/20 05:32 PM.

With a Charger born in Chrysler assembly plant in Valencia, Venezuela
Re: b body charging system.. [Re: NachoRT74] #2823825
09/22/20 08:35 PM
09/22/20 08:35 PM
Joined: Apr 2020
Posts: 14
canada
C
cwilson66 Offline OP
member
cwilson66  Offline OP
member
C

Joined: Apr 2020
Posts: 14
canada
put a new insolation washer under the second field terminal screw, and shes fixed thanks for all the help guys even tho this should have been pretty obvious. always learnin!

thanks
connor

Re: b body charging system.. [Re: cwilson66] #2824116
09/23/20 02:11 PM
09/23/20 02:11 PM
Joined: Sep 2003
Posts: 19,239
north of coder
moparx Offline
"Butt Crack Bob"
moparx  Offline
"Butt Crack Bob"

Joined: Sep 2003
Posts: 19,239
north of coder
happy to hear it was a simple fix ! up