I getting ready to reroof my house, to standing seam metal.
I have two toilets, 4 sinks, 2 showers, one washer.
I have an accessible attic.
Can I plumb all the current vents that pierce the current roof, into one single larger vent?

Purpose being to clean up roof clutter, move the main vent to back yard side of the roof, and reduce potential future leak sources?

Cost is not an object, but not sure if they will interact adversely, or long runs are a problem, or something else?


Last edited by jcc; 05/14/20 02:26 PM.

Reality check, that half the population is smarter then 50% of the people and it's a constantly contested fact.
Re: OT Home vent stack question for plumbers [Re: jcc] #2774542
05/14/20 03:14 PM
05/14/20 03:14 PM
Joined: Jun 2004
Posts: 3,372
St. Charles, MO
wingman Offline
Uncreative Title
wingman  Offline
Uncreative Title

Joined: Jun 2004
Posts: 3,372
St. Charles, MO
The short answer is probably yes this is allowed, but check your local codes.

The final vent size will then be driven by your sewer main size. Again check your local codes.

Also be sure the vent laterals are sloped correctly back to the house so condensation does not pool.


1969 Dodge Coronet Super Bee 383 A4
1970 Plymouth Road Runner 440 FC7 (sold)
Re: OT Home vent stack question for plumbers [Re: wingman] #2774623
05/14/20 06:43 PM
05/14/20 06:43 PM
Joined: Jan 2003
Posts: 3,122
Auburn WA
Dave_J Offline
master
Dave_J  Offline
master

Joined: Jan 2003
Posts: 3,122
Auburn WA
My house was built in 1983 and has only 1 DWV pipe exiting the roof. All the vent pipes from 3 baths and 1 kitchen are 2 inch and are tee'd into 1 3 inch stack vent. But I live 6 miles outside the city and county builder codes may have been different back then.

YMMV.


Retired, US ARMY 1973-1994
ASE mechanic, Electrical 1994-1997
Retired GTE/VERIZON/FRONTIER 1997-2015


Posting cheap tech help (CRAP) here since Nov 97, 1000's of posts, some may be good.

03 Suzuki Burgman 650(Burger King) Scooter
65 Formula S Cuda
78 Little Red Express Truck
98 Buick Regal (wifes car)
Re: OT Home vent stack question for plumbers [Re: Dave_J] #2774673
05/14/20 09:31 PM
05/14/20 09:31 PM
Joined: Feb 2003
Posts: 8,670
A
Andrewh Offline
master
Andrewh  Offline
master
A

Joined: Feb 2003
Posts: 8,670
I can't help but envision the collectors on a set of custom headers coming out of your roof.

Re: OT Home vent stack question for plumbers [Re: Andrewh] #2774676
05/14/20 10:00 PM
05/14/20 10:00 PM
Joined: Nov 2008
Posts: 1,565
tennessee
P
pushbutton Offline
pro stock
pushbutton  Offline
pro stock
P

Joined: Nov 2008
Posts: 1,565
tennessee
Google Studor Vent could help if you are going to have long runs to the main stack vent.

Re: OT Home vent stack question for plumbers [Re: Andrewh] #2774677
05/14/20 10:08 PM
05/14/20 10:08 PM
Joined: Dec 2003
Posts: 22,695
Bitopia
J
jcc Offline OP
If you can't dazzle em with diamonds..
jcc  Offline OP
If you can't dazzle em with diamonds..
J

Joined: Dec 2003
Posts: 22,695
Bitopia
Originally Posted by Andrewh
I can't help but envision the collectors on a set of custom headers coming out of your roof.


laugh2 laugh2 up


Reality check, that half the population is smarter then 50% of the people and it's a constantly contested fact.
Re: OT Home vent stack question for plumbers [Re: jcc] #2774703
05/14/20 11:29 PM
05/14/20 11:29 PM
Joined: Jan 2003
Posts: 1,908
Nebraska
4
4406bbl Offline
top fuel
4406bbl  Offline
top fuel
4

Joined: Jan 2003
Posts: 1,908
Nebraska
Not really an issue.....if you do not live in a freezing climate. The stack will freeze shut if you do and it gets real cold, most cold weather states required the stack to increase to the next size thru the roof for that reason. The new shacker houses with plastic pipe get thru inspections with a 3" stack, but it is wise to up it to 4 in a cold climate.

Re: OT Home vent stack question for plumbers [Re: 4406bbl] #2774705
05/14/20 11:31 PM
05/14/20 11:31 PM
Joined: Jan 2003
Posts: 15,715
Jefferson State
S
srt Offline
ESYC
srt  Offline
ESYC
S

Joined: Jan 2003
Posts: 15,715
Jefferson State
There are maximum runs to the common stack as well, and slope requirements to consider

Re: OT Home vent stack question for plumbers [Re: srt] #2774710
05/15/20 12:01 AM
05/15/20 12:01 AM
Joined: Jan 2003
Posts: 1,908
Nebraska
4
4406bbl Offline
top fuel
4406bbl  Offline
top fuel
4

Joined: Jan 2003
Posts: 1,908
Nebraska
And flow units, and vent fittings vs drain fittings, but a 4" stack is 160units, vs a 3" at 20 I think, so a 4" increased to 6"should handle anything he has, 1/4" per foot slope on the pipe.