Previous Thread
Next Thread
Print Thread
Voltage limiter is acting weird. #2695506
09/08/19 04:59 PM
09/08/19 04:59 PM
Joined: Dec 2012
Posts: 1,823
Wind Gap,Pa.
S
Sammy Offline OP
top fuel
Sammy  Offline OP
top fuel
S

Joined: Dec 2012
Posts: 1,823
Wind Gap,Pa.
1970 Challenger, no oil pressure reading, gas gauge goes up and then down and then nothing. Next day fuel gauge works then quits.
Is it the limiter or wiring issue?

Re: Voltage limiter is acting weird. [Re: Sammy] #2695507
09/08/19 05:01 PM
09/08/19 05:01 PM
Joined: May 2019
Posts: 6,221
nowhere
S
Sniper Offline
master
Sniper  Offline
master
S

Joined: May 2019
Posts: 6,221
nowhere
well, hard to say. It could be wiring to the limiter or it could be the limiter itself. Gonna have to get a meter on it,or just swap in a new limiter and see.

Re: Voltage limiter is acting weird. [Re: Sammy] #2695511
09/08/19 05:21 PM
09/08/19 05:21 PM
Joined: Jan 2003
Posts: 15,291
Omaha Ne
T
TJP Offline
I Live Here
TJP  Offline
I Live Here
T

Joined: Jan 2003
Posts: 15,291
Omaha Ne
May also be a flaky ground to the cluster, beer

Re: Voltage limiter is acting weird. [Re: TJP] #2695563
09/08/19 08:41 PM
09/08/19 08:41 PM
Joined: Jan 2003
Posts: 20,740
A collage of whims
topside Offline
Too Many Posts
topside  Offline
Too Many Posts

Joined: Jan 2003
Posts: 20,740
A collage of whims
Voltage limiter reduces voltage to the gauges down to 5V.
12V will fry the gauges.
Never had one go intermittent, last time one failed on me was many years ago.
Only the one problem out of 20-some old Mopars I've had over 40 years.
I'd suspect a poor ground or some loose connections from your description.

Re: Voltage limiter is acting weird. [Re: topside] #2695579
09/08/19 09:21 PM
09/08/19 09:21 PM
Joined: Dec 2012
Posts: 1,823
Wind Gap,Pa.
S
Sammy Offline OP
top fuel
Sammy  Offline OP
top fuel
S

Joined: Dec 2012
Posts: 1,823
Wind Gap,Pa.
Originally Posted by topside
Voltage limiter reduces voltage to the gauges down to 5V.
12V will fry the gauges.
Never had one go intermittent, last time one failed on me was many years ago.
Only the one problem out of 20-some old Mopars I've had over 40 years.
I'd suspect a poor ground or some loose connections from your description.



Where would I find the ground to the limiter?

Re: Voltage limiter is acting weird. [Re: Sammy] #2695589
09/08/19 09:40 PM
09/08/19 09:40 PM
Joined: Jan 2003
Posts: 10,534
Freeport IL USA
poorboy Offline
I Live Here
poorboy  Offline
I Live Here

Joined: Jan 2003
Posts: 10,534
Freeport IL USA
Originally Posted by Sammy
Originally Posted by topside
Voltage limiter reduces voltage to the gauges down to 5V.
12V will fry the gauges.
Never had one go intermittent, last time one failed on me was many years ago.
Only the one problem out of 20-some old Mopars I've had over 40 years.
I'd suspect a poor ground or some loose connections from your description.



Where would I find the ground to the limiter?


A bad ground would likely be the dash ground, the limiter grounds through the dash ground. Could make the dash lights (and turn indicators) do strange things as well.
The 1st think I think about with the nearly any old Mopar electrical issue is a ground issue. Fixing grounds solves a lot of their electrical problems. Gene

Re: Voltage limiter is acting weird. [Re: Sammy] #2695646
09/09/19 02:29 AM
09/09/19 02:29 AM
Joined: May 2006
Posts: 1,752
Phila
P
PhillyRag Offline
top fuel
PhillyRag  Offline
top fuel
P

Joined: May 2006
Posts: 1,752
Phila
The limiter supplies power to all 3 gauges. If ONLY the fuel gauge spiked, points to fuel sender unit as suspect. If ONLY the limiter wer acting up; you see weird fluctuation on ALL 3 gauges.

Re: Voltage limiter is acting weird. [Re: PhillyRag] #2695660
09/09/19 07:44 AM
09/09/19 07:44 AM
Joined: Dec 2012
Posts: 1,823
Wind Gap,Pa.
S
Sammy Offline OP
top fuel
Sammy  Offline OP
top fuel
S

Joined: Dec 2012
Posts: 1,823
Wind Gap,Pa.
Originally Posted by PhillyRag
The limiter supplies power to all 3 gauges. If ONLY the fuel gauge spiked, points to fuel sender unit as suspect. If ONLY the limiter wer acting up; you see weird flucuation on ALL 3 gauges.


Oil pressure was going up and down and now shows no activity.
Fuel goes normal and now keeps fluctuating.
Sometimes on and sometimes nothing.

Re: Voltage limiter is acting weird. [Re: Sammy] #2695675
09/09/19 09:01 AM
09/09/19 09:01 AM
Joined: Jan 2006
Posts: 3,535
Canuckville
68Cbarge Offline
master
68Cbarge  Offline
master

Joined: Jan 2006
Posts: 3,535
Canuckville
Replace the voltage limiter. I strongly suggest getting an electronic replacement and be done with it.
RTE sells electronic limiters on Ebay.
Also MR.Heaterbox builds and sells electronic limiters..

Just to be absolute sure...with a test light and the key on ACC or RUN,pull the wire from the sending unit,ground your test light and poke the plug for the sending unit. It should be dim and pulse on/off. If that does not happen the limitier is fried.
You can test the wire for the oil pressure and temperature gauges same way but with the key on run only.
Hope this helps,good luck.


'68 Newport Custom Barge on a Budget!! BOAB
1973 Satellite WAGON! 318- 3 on the tree!!
2008 Chrysler 300c HEMI!
Re: Voltage limiter is acting weird. [Re: 68Cbarge] #2695679
09/09/19 09:15 AM
09/09/19 09:15 AM
Joined: Dec 2012
Posts: 1,823
Wind Gap,Pa.
S
Sammy Offline OP
top fuel
Sammy  Offline OP
top fuel
S

Joined: Dec 2012
Posts: 1,823
Wind Gap,Pa.
Originally Posted by 68Cbarge
Replace the voltage limiter. I strongly suggest getting an electronic replacement and be done with it.
RTE sells electronic limiters on Ebay.
Also MR.Heaterbox builds and sells electronic limiters..

Just to be absolute sure...with a test light and the key on ACC or RUN,pull the wire from the sending unit,ground your test light and poke the plug for the sending unit. It should be dim and pulse on/off. If that does not happen the limitier is fried.
You can test the wire for the oil pressure and temperature gauges same way but with the key on run only.
Hope this helps,good luck.






Thanks this is what I'm looking for.

I was going over an old invoice when I bought the car and had it at a very reputable electrical shop and they did fix all the grounds and determined there was an issue.
They did fix it but now the problem reappeared.

Re: Voltage limiter is acting weird. [Re: 68Cbarge] #2695739
09/09/19 11:17 AM
09/09/19 11:17 AM
Joined: Nov 2003
Posts: 36,040
Lincoln Nebraska
R
RapidRobert Offline
Circle Track
RapidRobert  Offline
Circle Track
R

Joined: Nov 2003
Posts: 36,040
Lincoln Nebraska
Quote
Replace the voltage limiter. I strongly suggest getting an electronic replacement and be done with it.
RTE sells electronic limiters on Ebay.
Also MR.Heaterbox builds and sells electronic limiters..
This, tho if one gauge works & the other doesn't it would point to as mentioned an intermittent ground or an intermittent open but for sure get an electronic version rather than the OE electromechanical type which will wreak havoc if it ever full fields.


live every 24 hour block of time like it's your last day on earth






Powered by UBB.threads™ PHP Forum Software 7.7.1